RF Signal Chain

Noise Figure Formula & Friis Cascade

Noise figure formula, linear-to-dB conversion, Friis cascaded equation, noise temperature math, noise floor limits, and Y-factor measurement.

  • Noise figure
  • Friis cascade
  • Low-noise amplifier
  • Y-factor measurement
Machined aluminum coaxial low-noise amplifier module linked by blue braided coaxial cables to a cylindrical RF noise source ahead of a benchtop spectrum analyzer displaying a green noise trace
Coaxial low-noise amplifier and calibrated broadband noise source arranged on an RF bench ahead of an analyzer for Y-factor noise figure verification.

The noise figure formula expresses RF signal-to-noise degradation in decibels as NF = 10 log10(F), where linear noise factor F equals SNRi / SNRo at a 290 K input termination. For cascaded stages, convert every noise figure and available gain to linear ratios before applying Friis’s formula, Ftotal = F1 + (F2 − 1)/G1 + (F3 − 1)/(G1 · G2).

Browse the RF signal chain hub for system-level receiver planning. For heterodyne mixing and image-frequency geometry, consult RF, IF, and LO explained; for balancing LNA gain against mixer overload across receiver topologies, see RF transmitter and receiver module architecture; and for tying receiver noise figure into propagation losses, review RF link budget calculation and fade margin.

How Do Noise Factor and Noise Figure Relate in Equations?

Linear noise factor F is the unitless ratio of a device’s output noise power to thermal output noise from a matched 290 K input termination, equal to SNRi / SNRo. Noise figure NF expresses that linear noise factor in decibels as NF = 10 log10(F) = SNRi,dB − SNRo,dB.

Because every physical noisy component degrades signal-to-noise ratio so that input SNR exceeds output SNR, linear noise factor always satisfies F > 1, with lower values indicating better amplifier or receiver performance. Equivalently, separating an amplifier’s own output-referred added noise power Na from amplified input thermal noise Ni · G gives F = 1 + Na / (Ni · G).

IEEE and IRE Signal-Independent Definition at 290 K

Under the IEEE and IRE noise factor definition documented by Stanford, noise factor is defined independently of input or output signal level as the ratio of available output noise power from the actual noisy stage to the output noise of an ideal noiseless stage having identical available power gain and noise bandwidth.

The standard reference temperature is fixed at T0 = 290 K under IEEE Std 100-1972 in NIST’s noise metrology guide, where kT/e equals 0.0250 volt and the thermal energy product kB T equals 4.00 × 10^-21 Joules, a convenient round figure near room temperature. Both SNR-difference and linear noise factor equations remain valid only when the input termination is held at T0 = 290 K.

In heterodyne receivers, output noise includes spurious noise translated from the image frequency while the standard thermal input reference counts only noise arriving via the principal frequency transformation; see mixer image rejection and LO side selection for preselection planning. Under 57 IRE 7.S2, heterodyne networks therefore define a separate noise factor for each corresponding input-output frequency pair.

Passive Attenuators and Lossy Networks

For a passive network containing no active components, such as an attenuator, bandpass filter, or matching network held at physical temperature T0, the linear noise factor equals its attenuation ratio L, which is the inverse of available power gain (F = 1 / G), so NF = −G(dB). As shown in UC Santa Barbara amplifier notes, a 10 dB attenuator with available gain Gav = −10 dB has a noise figure of 10 dB. When an attenuator operates at a physical temperature T different from T0, its noise temperature becomes Te = (L − 1) T and its noise factor generalizes to F = 1 + (L − 1) T / T0.

Quantity Symbol Formula Unit Key Validity Condition
Linear noise factor F F = SNRi / SNRo = 1 + Na / (Ni · G) Unitless ratio (F > 1) Matched input termination at T0 = 290 K; Ni = k T0 B
Decibel noise figure NF NF = 10 log10(F) = SNRi,dB − SNRo,dB dB Valid for 290 K thermal input termination
Passive attenuator at T0 F, NF F = L = 1 / G; NF = −G(dB) Unitless ratio / dB Passive network at T = 290 K (10 dB attenuator has NF = 10 dB)
Passive attenuator at arbitrary T Te, F Te = (L − 1) T; F = 1 + (L − 1) T / T0 K / unitless ratio Accounts for physical attenuator temperature differing from T0
Standard thermal energy kB T0 4.00 × 10^-21 Joules (kT/e = 0.0250 volt) J (or −174 dBm/Hz in 1 Hz) IEEE Std 100-1972 standard reference temperature of 290 kelvins

What Is the Friis Formula for Cascaded Noise Figure?

Named after Harald T. Friis, the Friis cascaded noise factor equation computes linear total noise factor across n matched stages as Ftotal = F1 + (F2 − 1)/G1 + (F3 − 1)/(G1 · G2) + (F4 − 1)/(G1 · G2 · G3) + … + (Fn − 1)/(G1 · G2 … Gn−1), then converts via NFtotal = 10 log10(Ftotal).

Linear Ratio Conversion and Available Gain Requirements

Both stage noise factor Fi and stage power gain Gi must enter Friis’s formula as linear ratios rather than decibel values. Substituting raw decibels directly into the denominator or excess-noise numerators produces severe calculation errors because noise powers add linearly while gains multiply linearly across the cascade.

Cascaded noise analysis specifies available power gain GA for every stage because thermal noise power is defined as available power, keeping stage-to-stage referral mathematically consistent under matched impedances. Inside the cascade, each component’s individual noise factor still assumes an input termination at the standard noise temperature rather than the amplified noise exiting the preceding stage, so every stage’s added noise contribution remains independent. Across the full chain, total output SNR in decibels satisfies (S/N)OUT dB = (S/N)IN dB − NFtotal.

First-Stage LNA Dominance and Second-Stage Degradation Threshold

Because every stage beyond the first has its excess noise factor (Fi − 1) divided by the cumulative linear available gain of all preceding stages, the first amplifying stage—the low-noise amplifier (LNA)—predominantly governs system sensitivity according to Freceiver = FLNA + (Frest − 1)/GLNA.

Even so, a designer cannot ignore downstream noise blindly. Second-stage noise still measurably degrades overall SNR whenever the first stage’s noise figure plus its gain in decibels is not much greater than the noise figure of the second stage.

Why Front-End Passive Loss Ahead of the LNA Hurts Twice

Placing a passive lossy element ahead of the first amplifier—such as a shared-antenna switch, limiter, or duplexer evaluated in TDD vs. FDD front-end isolation—directly penalizes both the additive first-stage noise factor and the denominator that suppresses downstream noise. Written in equivalent noise-temperature form, Friis’s equation is TE = T1 + T2 / G1 + T3 / (G1 · G2) + …, yielding NF = 10 log10(1 + TE / 290). As a direct corollary of the Friis equation, placing a 6 dB attenuator ahead of the first amplifier sets linear stage-1 gain G1 to one quarter, which quadruples the amplifier’s effective noise temperature contribution (TE = T1 + 4 T2 + …) on top of adding the attenuator’s own noise temperature T1.

Three-stage Friis cascaded noise factor diagram showing Stage 1 DUT/LNA, Stage 2 Preamplifier, and Stage 3 Analyzer, the dB-to-linear conversion rule, Friis equation, and side-by-side comparison dropping total NF from 20 dB without a preamp to 2.3 dB with a 30 dB, 1 dB NF preamp
Converting stage NF and gain to linear ratios before applying Friis’s formula shows how inserting a 30 dB, 1 dB NF preamplifier cuts total cascaded noise figure from 20 dB down to 2.3 dB ahead of a 30 dB NF analyzer.

How Do You Convert Noise Figure to Effective Noise Temperature?

To convert noise figure to effective input noise temperature, first convert decibel NF to linear noise factor F, then apply Te = 290(F − 1) in kelvins. Inversely, convert effective noise temperature back to linear noise factor via F = 1 + Te / T0 and decibel noise figure via NF = 10 log10(1 + Te / 290).

Noise temperature expresses available noise power spectral density directly in kelvins through the Johnson-Nyquist relation PN / B = kB T, where Boltzmann’s constant kB equals 1.381 × 10^-23 J/K and B is measurement bandwidth in hertz. In a complete receiver, overall system noise temperature TS equals the sum of antenna noise temperature TA and the composite effective noise temperature TE of the transmission lines and receiver referred to the antenna terminals (TS = TA + TE).

Terrestrial Receivers vs. Cold-Space Satellite Front Ends

Noise figure works well for terrestrial radio receivers whose antennas see an effective temperature near room temperature (290 K), because lowering receiver noise figure by 2 dB yields roughly a 2 dB improvement in output SNR. When an amplifier with an effective noise temperature of 870 K—corresponding to a 6 dB noise figure—amplifies a 290 K thermal source, inserting the amplifier degrades SNR by 6 dB.

By contrast, satellite receiver antennas pointed toward cold space see antenna temperatures well below 290 K, so a 2 dB improvement in receiver noise figure produces more than a 2 dB gain in output SNR. UC Santa Barbara’s worked conversion demonstrates why satellite engineers prefer kelvins over room-temperature decibels:

  • At room temperature (T0 = 290 K), an amplifier with NF = 1 dB has linear noise factor F = 1.26 and effective input noise temperature Te = 75 K, raising equivalent source temperature to 290 + 75 = 365 K—a modest increase over the source itself.
  • Against a cold-space antenna with TA = 20 K, that identical 75 K amplifier lifts total system noise temperature to 20 + 75 = 95 K, producing an effective noise factor F = 1 + 75 / 20 = 4.5 (NF = 7 dB) relative to the cold sky.
Operating Benchmark Noise Figure (dB) Linear Noise Factor F Effective Noise Temp Te (K) Source Temp (K) Combined System Temp (K) Practical Interpretation
Room-temperature LNA (1 dB NF) 1 dB 1.26 75 K 290 K 365 K Modest noise rise above 290 K source; small extra gain from further NF cuts
Cold-space satellite LNA (same 75 K unit) 7 dB (relative to 20 K sky) 4.5 (relative to 20 K) 75 K 20 K 95 K Major relative degradation hidden by room-temperature 1 dB NF rating
Higher-noise terrestrial amplifier 6 dB Computed from 1 + Te / 290 870 K 290 K 290 K + 870 K Degrades 290 K thermal source SNR by 6 dB

What Is the Difference Between Noise Figure and Noise Floor?

Noise figure is a dimensionless decibel ratio describing how much a component or receiver degrades SNR relative to a 290 K thermal source, whereas the noise floor is the absolute background noise power level—measured in dBm or dBm/Hz—formed by summing all unwanted noise sources inside a measurement system.

A practical RF budget distinguishes two floor types. An instrumentation noise floor arises when internal receiver noise (such as an analyzer with a high noise figure) dominates the baseline, whereas a physical noise floor is governed by external thermal, blackbody, cosmic, atmospheric, or incidental man-made noise. At the digitizer stage, every additional 6.02 dB of noise floor causes a 1-bit reduction in the effective number of bits (ENOB) of an analog-to-digital or digital-to-analog converter.

Thermal Noise Density and Minimum Detectable Signal (MDS)

At the standard 290 K reference temperature in a 1 Hz bandwidth, available thermal noise power is Pav = 4 × 10^-21 watt—independent of source resistance—which converts to −174 dBm/Hz. Expanding to any noise equivalent bandwidth B scales available thermal noise power by 10 log B; for a 1000 Hz bandwidth, thermal noise power becomes −174 + 10 log(1000) = −174 + 30 = −144 dBm.

Combining thermal density, bandwidth, and receiver noise figure yields the minimum detectable signal (PMDS) at S = N (0 dB SNR): PMDS = −174 dBm/Hz + 10 log B + NF (dB). For a typical spectrum analyzer with NF = 25 dB and GAV = 1 (0 dB), narrowing resolution bandwidth directly lowers the displayed output noise floor:

Resolution Bandwidth (RBW) Thermal Density at 290 K (dBm/Hz) Analyzer Gain GAV Analyzer NF (dB) Analyzer Output Noise Floor NAVO (dBm)
1 kHz −174 dBm/Hz 1 (0 dB) 25 dB −119 dBm
10 kHz −174 dBm/Hz 1 (0 dB) 25 dB −109 dBm
100 kHz −174 dBm/Hz 1 (0 dB) 25 dB −99 dBm

How Do You Work Through a Noise Figure Calculation Example?

Work through any noise figure calculation in four disciplined steps: compute input thermal noise from −174 dBm/Hz + 10 log B, convert every stage’s decibel NF and available gain to linear ratios, evaluate Friis’s sum term by term, and convert the resulting linear Ftotal back to decibels via 10 log10(Ftotal).

Single-Stage SNR Degradation and Bandwidth Scaling

Consider a single-stage amplifier with NF = 3 dB receiving an available signal power of −113 dBm:

  1. Wide bandwidth (bandwidth factor 10 log10 B = 60 dB): Available thermal input noise is Navi = −174 + 60 = −114 dBm. Input SNR equals −113 − (−114) = 1 dB, and subtracting the 3 dB noise figure drops output SNR to 1 dB − 3 dB = −2 dB.
  2. Narrowed bandwidth (bandwidth factor reduced to 50 dB): Available thermal input noise falls to Navi = −174 + 50 = −124 dBm. Against the same −113 dBm signal, input SNR climbs to 11 dB and output SNR rises to 8 dB—demonstrating how reducing noise bandwidth improves SNR far more than small incremental noise figure trims alone.

Two-Stage vs. Three-Stage Friis Cascade With a Preamplifier

When measuring a low-noise device under test (DUT) with a spectrum analyzer, Friis’s formula exposes why a noisy second stage overwhelms modest first-stage gain—and why adding a low-noise preamplifier restores accuracy.

  • Two-stage chain (DUT directly into spectrum analyzer): Stage 1 DUT has G1 = 10 dB (linear 10) and F1 = 2 dB (linear 1.58). Stage 2 spectrum analyzer has F2 = 30 dB (linear 1000). Substituting linear values gives FTOTAL = 1.58 + (1000 − 1) / 10 = 1.58 + 999 / 10 = 101.5, or 20 dB total noise figure—completely dominated by the spectrum analyzer.
  • Three-stage chain (30 dB / 1 dB NF preamplifier inserted ahead of analyzer): Keeping Stage 1 at G1 = 10 dB (linear 10) and F1 = 2 dB (linear 1.58), inserting Stage 2 preamplifier with G2 = 30 dB (linear 1000) and F2 = 1 dB (linear 1.26) ahead of Stage 3 analyzer F3 = 30 dB (linear 1000) yields FTOTAL = 1.58 + (1.26 − 1) / 10 + 999 / (10 × 1000) = 1.71, or 2.3 dB total noise figure.
Cascade Configuration Stage 1 (DUT) Stage 2 Stage 3 Linear Friis Expansion Total Linear Ftotal Total Cascaded NF (dB)
DUT directly into analyzer G1 = 10 dB (10), F1 = 2 dB (1.58) Analyzer F2 = 30 dB (1000) None 1.58 + 999 / 10 101.5 20 dB (analyzer dominates)
DUT + low-noise preamp + analyzer G1 = 10 dB (10), F1 = 2 dB (1.58) Preamp G2 = 30 dB (1000), F2 = 1 dB (1.26) Analyzer F3 = 30 dB (1000) 1.58 + (1.26 − 1)/10 + 999/(10 × 1000) 1.71 2.3 dB (DUT measurable)

How Does a Noise Figure Meter Measure an Amplifier?

A noise figure meter automates the hot-cold Y-factor method by toggling a calibrated broadband noise source ON and OFF at the amplifier input, measuring the ratio of hot-to-cold output noise power Y = N2 / N1, and solving for linear noise factor F = YS / (Y − 1) without needing separate gain-bandwidth measurements.

Measuring noise figure directly from textbook SNR ratios is impractical on a bench because signal power cannot be isolated from noise cleanly, test receivers inject their own internal noise, and precise gain-bandwidth products are notoriously hard to measure. Switching a noise source between a cold temperature (T0 = 290 K) and a hot effective noise temperature (Th) places two measured points on a straight line of output noise versus source temperature whose slope reflects gain and bandwidth while the y-intercept isolates the stage’s added noise Na.

ENR, Gain-Bandwidth Cancellation, and Avalanche Noise Sources

Defining excess temperature as Tex = Th − T0, the normalized ratio Tex / T0 is called Excess Noise Ratio (ENR) when noise power is measured into a standard 50-unit matched load (written in decibels as ENR(dB) = 10 log10(TH / T0 − 1)). When the wideband noise source spans a bandwidth much wider than the device under test, dividing the source-ON output power P2 by the source-OFF output power P1 cancels both transducer gain and noise equivalent bandwidth B, leaving F = YS / (Y − 1) in linear ratios before converting via NF = 10 log F.

Commercial microwave noise sources frequently use reverse-biased avalanche diodes to generate high, flat white excess noise that switches rapidly ON and OFF. Because diode impedance shifts between the ON and OFF bias states, manufacturers incorporate an output attenuator inside the noise source—trading some excess noise output to minimize impedance mismatch variation between states.

Tunable Meter Architecture and Through-Adapter Calibration

A tunable noise figure meter operates as a dedicated receiver: an internal mixer upconverts the input noise band to a 2 GHz power meter via fin = 2 GHz − fLO so the IF filter sets the measurement bandwidth, while a square-wave drive gates the noise source ON and OFF to capture both noise figure and DUT gain simultaneously.

Before inserting the amplifier under test, accurate measurement requires a disciplined setup sequence:

  1. Load source ENR and temperature: Enter the noise source’s frequency-dependent ENR calibration table and case temperature (using 21 C as the default room-temperature setting).
  2. Calibrate with a through adapter: Connect the noise source to the preamplifier and analyzer using the exact measurement cables joined by a through adapter (barrel) so the meter measures and stores the receiver-chain second-stage noise contribution.
  3. Insert DUT and recalibrate on hardware changes: Replace the barrel with the DUT amplifier between the noise source and preamplifier; recalibrate whenever the noise source, preamplifier, or coaxial cables change.
Two-panel Y-factor hot/cold noise figure diagram with a bench setup showing a gated calibrated noise source, DUT amplifier with through-adapter calibration bypass, preamplifier, and noise figure meter on the left, and a linear plot of output noise power versus source temperature showing x-intercept minus Te, y-intercept Na, Cold 290 K point, and Hot Th point on the right
The Y-factor bench setup gates a calibrated noise source between cold (T0 = 290 K) and hot (Th) states so the two measured output noise powers define a straight line whose slope and intercepts yield F and −Te directly.

Front-End Cascade and First-Stage Gain Verification Checklist

Before finalizing a receiver front-end noise budget or bench test plan, verify unit conversion, passive front-end loss, first-stage gain headroom, antenna temperature regime, and calibration state in one engineering checklist.

Verification Check Governing Relation or Threshold Failure Mode Caught Required Design / Bench Action
Linear conversion before Friis Convert NF (dB) to linear F and GdB to linear available gain GA before summing Plugging raw decibels directly into Friis’s equation Record both dB and linear F, G columns for every stage prior to cascade math
Passive loss ahead of LNA Passive network at 290 K has F = L, NF = −G(dB); 6 dB input loss quadruples T2 Omitting pre-LNA filter, switch, or cable insertion loss Place every pre-LNA passive loss as Stage 1 ahead of the LNA in the Friis chain
First-stage gain headroom Stage 1 NF + G1 (dB) must greatly exceed Stage 2 NF Noisy mixer or 30 dB NF analyzer swamping a 10 dB gain DUT (20 dB total NF) Verify Stage 1 gain suppresses Stage 2 term, or insert a low-noise preamplifier
Reference temperature regime Standard NF assumes T0 = 290 K; TS = TA + TE for arbitrary antennas Misreading 1 dB room-temp NF (75 K) on a 20 K cold-sky satellite link (7 dB effective) Convert to kelvins via Te = 290(F − 1) whenever antenna temperature departs far from 290 K
Noise floor and bandwidth budget PMDS = −174 dBm/Hz + 10 log B + NF (dB); 6.02 dB costs 1 bit ENOB Confusing relative NF (dB) with absolute noise floor (dBm) Specify noise equivalent bandwidth B alongside NF when budgeting sensitivity
Y-factor calibration hygiene Load per-source ENR table, 21 C room temp default, and barrel through-cal Stale ENR table or uncalibrated cable/preamp swap biasing Y = N2 / N1 Run through-adapter calibration with final test cables before inserting the DUT

Frequently asked questions

What is the noise figure formula in linear and decibel form?

Linear noise factor F equals the unitless ratio of input signal-to-noise ratio to output signal-to-noise ratio (F = SNRi / SNRo) referenced to a matched input termination at standard temperature T0 = 290 K. Noise figure converts that ratio to decibels via NF = 10 log10(F), which equals SNRi,dB minus SNRo,dB.

Why must you convert dB to linear ratios before using the Friis formula?

Friis's cascaded noise equation sums linear noise powers divided by preceding linear available power gains: Ftotal = F1 + (F2 − 1)/G1 + (F3 − 1)/(G1 · G2). Substituting decibel figures directly breaks the linear power-ratio weighting and produces an invalid system noise figure.

When should RF engineers use effective noise temperature instead of noise figure?

Convert noise figure in decibels to linear noise factor F first, then apply Te = 290(F − 1) in kelvins whenever antenna temperature departs far from 290 K. For example, a 1 dB noise figure corresponds to linear F = 1.26 and an effective input noise temperature of 75 K, while a 6 dB noise figure corresponds to 870 K.

How does receiver noise figure raise the noise floor and minimum detectable signal?

Noise figure is a dimensionless decibel ratio measuring how much an amplifier or receiver degrades SNR relative to a 290 K thermal source. Noise floor is an absolute noise power level in dBm combining −174 dBm/Hz thermal density, noise equivalent bandwidth (10 log B), and receiver noise figure.

How does a noise figure meter measure an amplifier without knowing exact bandwidth?

A noise figure meter automates the hot-cold Y-factor method by switching a calibrated broadband noise source ON and OFF and taking the output noise power ratio Y = N2 / N1. Dividing the two noise powers cancels both transducer gain and noise equivalent bandwidth, leaving F = YS / (Y − 1).

Sources

  1. Measuring Noise Figure — Stanford University
  2. Performance Limitations of Amplifiers — University of California, Santa Barbara
  3. The Measurement of Noise Performance Factors: A Metrology Guide — National Institute of Standards and Technology

About the author

Editor, RF and microwave components

Editor of MicroSource Insights. Sets the sourcing standard each guide is held to, and owns the correction path when a published claim proves wrong.